Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders

Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders
Author :
Publisher :
Total Pages : 88
Release :
ISBN-10 : OCLC:52183485
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders by : Thomas E. Cousins

Download or read book Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders written by Thomas E. Cousins and published by . This book was released on 2003 with total page 88 pages. Available in PDF, EPUB and Kindle. Book excerpt: Encouraged by the performance of high performance normal weight composite girders, the Virginia Department of Transportation has sought to exploit the use of high performance lightweight composite concrete (HPLWC) girders to achieve economies brought about by the reduction of dead loads in bridges. Transfer length measurements (conducted on two AASHTO Type IV HPLWC prestressed girders) indicated an average transfer length of 17 inches, well below the AASHTO and ACI requirements. Two HPLWC AASHTO Type II girders and a 48 x 8 inch normal weight 4000-psi concrete deck were fabricated. The girders were cast of concretes with a compressive strength of 6380 psi and a unit weight of 114 pcf. Full scale testing of the girders was conducted to evaluate development length and flexural strength in HPLWC composite girders. Embedment lengths of five, six, and eight feet were evaluated. Tests indicated a development length of about 72 inches, marginally below the ACI and AASHTO requirements. All tested girders exceeded their theoretical flexural capacity by 24% to 30%. A third composite Type II girder was cast of high performance normal weight concrete and topped with a 48 x 8 inch normal weight 4000-psi concrete deck. This girder was intended as a control specimen. Prestress losses in the HPLWC AASHTO Type IV girders monitored over a nine-month period were found to be less than those calculated using the ACI and PCI models.


Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders Related Books

Investigation of Transfer Length, Development Length, Flexural Strength, and Prestress Losses in Lightweight Prestressed Concrete Girders
Language: en
Pages: 88
Authors: Thomas E. Cousins
Categories: Concrete bridges
Type: BOOK - Published: 2003 - Publisher:

DOWNLOAD EBOOK

Encouraged by the performance of high performance normal weight composite girders, the Virginia Department of Transportation has sought to exploit the use of hi
Investigation of Transfer Length, Development Length, Flexural Strength and Prestress Loss Trend in Fully Bonded High Strength Lightweight Prestressed Girders
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2002 - Publisher:

DOWNLOAD EBOOK

Cousins Encouraged by the performance of high performance normal weight composite girders, Virginia Department of Transportation has sought to exploit the use o
Specifications for Structural Concrete, ACI 301-05, with Selected ACI References
Language: en
Pages: 660
Authors: American Concrete Institute
Categories: Concrete
Type: BOOK - Published: 2005 - Publisher: American Concrete Institute

DOWNLOAD EBOOK

Mariam wa al Masih
Language: en
Pages:
Authors:
Categories:
Type: BOOK - Published: 2004 - Publisher:

DOWNLOAD EBOOK

Prestress Losses in Pretensioned High-strength Concrete Bridge Girders
Language: en
Pages: 73
Authors: Maher K. Tadros
Categories: Technology & Engineering
Type: BOOK - Published: 2003 - Publisher: Transportation Research Board

DOWNLOAD EBOOK

"The HCM includes three printed volumes (Volumes 1-3) that can be purchased from the Transportation Research Board in print and electronic formats. Volume 4 is